<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-11 07-09-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 61 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.8 kHz -83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 19139 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,87 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/12/11 7.08.02 Total samples: 19139 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 6,4 dBr MIN: 2,7 dBr AVE: 4,87 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2024/12/11 7.08.01) 06.54 06.56 06.58 07.00 07.02 07.04 07.06 07.08 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]